BT-120 Breaker Tracer Users Manual • • • • Mode d’emploi Bedienungshandbuch Manual d’Uso Manual de uso
BT-120 Breaker Tracer English Users Manual October 2009, Rev.1 ©2009 Amprobe Test Tools. All rights reserved.
Limitation of Liability Your Amprobe product will be free from defects in material and workmanship for 1 year from the date of purchase. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Amprobe’s behalf.
BT-120 Breaker Tracer 1 6 2 7 4 5 3 1 Sensor Location 2 Identification Arrow LED indicator 3 Battery Compartment 4 ON/OFF Switch 5 Adaptor Prongs 6 Transmitter power LED indicator 7 Receiver power LED indicator
BT-120 Breaker Tracer CONTENTS SYMBOLS AND WARNINGS...................................................................................2 Safety Information . ..........................................................................................2 Warnings and Precautions.................................................................................3 UNPACKING AND INSPECTION..............................................................................3 INTRODUCTION........................................
SYMBOLS Battery Caution ! Refer to the Manual Double Insulated Dangerous Voltage Alternating Current Earth Ground Direct Current Application around and removal from hazardous live conductors is permitted � Complies with European Directives Do not dispose of this product as unsorted municipal waste. Contact a qualified recycler for disposal. � Conforms to relevant Australian standards Underwriters Laboratories. [Note: Canadian and US.
• Do not operate the instrument in an explosive atmosphere. • To reduce the risk of fire or electric shock, do not expose this product to rain or moisture. • The meter is intended only for indoor use. To avoid electrical shock hazard, observe the proper safety precautions when working with voltages above 60 VDC, 42.4 Vpk, or 30 VAC rms. These voltage levels pose a potential shock hazard to the user.
OPERATION Breaker and Fuse Identification 1. Plug the transmitter into an energized 120V wall outlet. Refer to Fig.1. Fig. 1 Cir Tra c u it n sm Tra it te c er r 2. Make sure the red LED is ON to indicate that the outlet is energized. 3. Push the Power switch on the receiver to turn it ON. The receiver will beep and the Power LED will be lit. 4. At the breaker panel or fuse box, hold the receiver perpendicular to the breakers. Scan slowly all breakers once to calibrate the receiver.
SPECIFICATIONS Operating & Detection Voltage for Transmitter: Model BT-120, 90-120 VAC, Not to exceed ±10% (inclusive in rating) Operating Frequency: 50 - 60 Hertz Storage Temperature: 0-40 Degrees C. OperatingTemperature: 0-40 Degrees C. Sensitivity Adjustment: Automatic PowerSupply: 9-Volt Alkaline Battery.
SPEZISCHE ANWEISUNGEN Gebrauchs- und Findungs -spannung fur den Sender Ausführung: BT-120 90-120 V Wechselstrom ±10% nicht zu uberschreit en (inklusiv in Quoten) Gebrauchsfrequenz: 50-60 Herz Lagerungstemperatur: 0-40 Grad Celsius Gebrauchstemperatur: (während Laufzeit) 0-40 Grad Celsius Empndlichkeitseinstellung: Automatisch Strombedarf: 9-Volt Alkali Batterie (Nur für Empfänger) Polarität des Senders: Automatisch Luftfeuchtigkeit: 50% relative Luftfeuchtigkeit (unkondensbar) Umweltbedingungen: Für Innenbe
BATTERY REPLACEMENT Power is supplied by 9V Alkaline Battery x1 The Identification Arrow LED on the receiver will not turn ON when replacement is needed. To replace the battery, remove the screw from the back of the meter and slide the battery door outward. Remove the battery from case bottom and replace it with a fresh 9V Alkaline battery.