User Manual
13
Non-contact voltage
sensitivity (with probe)
LED illuminates and beeps at approximately 3 mm
(0.12 in) distance from a wire carrying 120 Vac
LED illuminates and beeps at approximately 5 mm
(0.2 in) distance from a wire carrying 230 Vac
Drop proof
1 meter
Operating time
One second ON, one second OFF for maximum
five cycles and wait for 1 minute before making
another measurement
Operating temperature
-10
O
C to +50
O
C (14
O
F to 122
O
F) ≤85% RH
Storage temperature
-10
O
C to +50
O
C (14
O
F to 122
O
F) ≤85% RH
Operating altitude
Up to 2000 meters
Battery
1 x 9V lithium or alkaline battery only,
6LR61/6LF22/MN1604 or equivalent
Battery life
500 tests (alkaline typically)
Dimensions
(L x W x H)
Approximately 170 x 40 x 24 mm
(6.69 x 1.57 x 0.94 in)
Weight
Approximately 80 g (0.18 lb) with battery
installed
Safety compliance
IEC 61010-1, UL 61010-1
CAN/CSA-C22.2 No. 61010-1-2004
EMC compliance
IEC 61326-1
Certification
CSA and CE
MAINTENANCE AND REPAIR
If the instrument fails to operate, check the battery and replace as
necessary.
Do the following:
1. Replace the battery if the tester does not work.
2. If antenna is not working, check the antenna connection. Make sure the
antenna is locked and secured.
3. Review the users manual to better understand how the tester operates.