User Manual

B-Cream & B-cream HD
34
ENGLISH
4 SUPER SERVICE MODE – ADJUSTING THE MANUFACTORY PARAMETERS
By switching on the dispenser using the master switch and holding down keys A and H simultaneously, the machine can be started
up in Super Service Mode and make adjusting the manufactory parameters. The dispenser will function normally, but it will be pos-
sible to modify the production parameters and any modifications carried out will be stored in the memory for the next time the dispen-
ser is switched on in normal mode.
For information on how to adjust the production parameters, please refer to the instructions for the operation parameters.
LIST OF PRODUCTION PARAMETERS B-CREAM 1/2/3
LIST OF PRODUCTION PARAMETERS B-CREAM HD 1/2/3
PA07 Lock Keypad. 0 / 1 / 2 0
PA08 Scale representation of temperature. C…F C
PA09 Firmware version display circuit board.
2015 version : enabling defrost timer.
Visualisation only
ON / OFF OFF
PA10 Firmware version power circuit board.
2015 version : counter machine life
Visualisation only
Days 0
IMPORTANT
Incorrect adjustment of the Production Parameters may compromise the opera-
tion of the machine.
IMPORTANT
Distributors in more containers from the factory parameters PA11 to PA 27 are
common to all the distributor and therefore can only be adjusted by the control
panel on the right container.
NAME DESCRIPTION ADJUSTMENT INTERVAL DEFAULT VALUE
PA11 Ice Cream Production Mode Density 1…10 8
PA12 Ice Cream Production Mode Density Hysteresis 0...4,0 0,2
PA13 Ice Cream Production Mode Temperature Hysteresis 0…5 °C 0,5
PA14 Compressor lockout time OFF 0…600 s 180
PA15 Electrovalve lockout time OFF 0…600 s 180
PA16 Time for which the density must remain above the reference value 0…60 s 1
PA17 Conservation Mode Temperature Hysteresis 0…5 °C 0,5
PA18 Maximum motor absorption 0…100 W 90
PA19 Motor cooling time 0…600 s 90
PA20 Motor protection intervention delay 0…60 s 5
PA21 Product conservation alarm temperature 0…10 °C 4
PA22 Tap sensor entry activation ON…OFF OFF
PA23 Temperature probe offset ? 0
PA24 Number of motor poles 0…1000 300
PA25 Motor control proportional P constant 0…1000 4
PA26 Motor control integral I constant 0…1000 0
PA27 Motor control derivative D constant YES…NO NO
NAME DESCRIPTION ADJUSTMENT INTERVAL DEFAULT VALUE
PA11 Ice Cream Production Mode Density 1…10 8
PA12 Ice Cream Production Mode Density Hysteresis 0...4,0 0,2
PA13 Ice Cream Production Mode Temperature Hysteresis 0…5 °C 0,5
PA14 Compressor lockout time OFF 0…600 s 180