Specifications
CURR:TRIG
This command programs the pending current trigger level of the power supply. The pending current trigger
level is a stored value that is transferred to the output terminals when a trigger occurs. A pending triggered
level is unaffected by subsequent CURR commands and remains in effect until the trigger subsystem
receives a trigger or an ABORt command is given. If there is no pending trigger level, then the query form
returns the immediate current limit level.
Command Syntax
Parameters
Default Suffix
*RST Value
Examples
Query Syntax
Returned Parameters
Related Commands
CURRent[:LEVel]:TRIGgered <channel> <NRf>
<channel>: 1 – 31, channel number
<NRf>: minimum to maximum current value of the channel
A
1.0
CURR:TRIG 1 12.000; CURR:LEV:TRIG 1 1.2
CURRent[:LEVel]:TRIGgered? <channel>
CURRent[:LEVel]:TRIGgered? <channel> MAX
CURRent[:LEVel]:TRIGgered? <channel> MIN
<NRf>
CURR:TRIG? returns the presently programmed triggered level.
If no triggered level is programmed, the CURR level is returned.
CURR:TRIG? MAX and CURR:TRIG? MIN return the maximum
and minimum programmable triggered current levels.
ABOR; CURR; *RST
CURR:PROT:CLE
This command clears the over-current protection status, and it dose not clear the over-current protection
setting (CURR:PROT:STAT). After this command, output remains in OFF state.
Command Syntax
Parameter
Example
Query Syntax
Related Commands
CURRent:PROTection:CLEar <channel>
<channel>: 1-31, channel number
CURR:PROT:CLE 1
(None)
CURR:PROT:STAT
CURR:PROT:STAT
This command enables or disables the power supply over-current (OC) protection function. If the over-
current protection function is enabled and the power supply goes into constant current (CC) mode, then the
output is disabled and the Questionable Condition status register OC bit is set (STAT:QUES?). An over-
current status can be cleared with the OUTP:PROT:CLE command.
Command Syntax
Parameters
*RST Value
Examples
Query Syntax
Returned Parameters
Related Commands
CURRent:PROTection:STATe <channel> <bool>
<channel>: 1 – 31, channel number
<bool>: 0 | 1 | OFF | ON
OFF
CURR:PROT:STAT 1 0; CURR:PROT:STAT 1 ON
CURRent:PROTection:STATe? <channel>
0 | 1
OUTP:PROT:CLE; *RST
6-23