Specifications
LIST:CURR:STEP
This command specifies how current list sequencing occurs in response to enabling current list state
(LIST:CURR:STAT). If default step (NONE) or AUTO is sent, enabling list operation state causes the
current list to sequence through all its points. The time that a list remains at each point is as specified in the
dwell list. As soon as the dwell interval expires, the list moves to the next point. If ONCE is sent, after
enabling list operation state, a single trigger advances a list only one point. After the specified dwell
interval, the list remains at that point until the next trigger occurs.
In either mode, triggers that occur during a dwell interval are ignored.
Command Syntax
Parameters
*RST Value
Examples
Query Syntax
Returned Parameters
Related Commands
LIST:CURRent:STEP <channel> <CRD>
<channel>: 1 – 31, channel number
<CRD>: NONE | AUTO | ONCE, list step
NONE
LIST:CURR:STEP 1 ONCE; LIST:CURR:STEP 2 AUTO
LIST:CURRent:STEP? <channel>
<CRD>: NONE | AUTO | ONCE, list step
LIST:CURR; LIST:CURR:STAT; LIST:CURR:TIME
LIST:CURR:TIM
This command sets the dwelling time for the output current list of the specified point. Each point specifies
the time, in milliseconds, that the output of the power supply is to remain at the level specified by the
corresponding point in the current list if the CURR:LIST:STEP is set to NONE or AUTO. At the end of
the dwell time, the output of the power supply is set to OFF.
Command Syntax
Parameters
Default Suffix
Examples
Query Syntax
Returned Parameters
Related Commands
LIST:CURRent:TIMe <channel> <point> <NR1>
<channel>: 1 – 31, channel number
<point>: list point number
<NR1>: 1 – 99990, dwelling time
ms
LIST:CURR:TIM 1 10 1000
LIST:CURRent:TIMe? <channel> <point>
<NR1> dwelling time
LIST:CURR:STAT
LIST:VOLT
This command specifies the output voltage points in a list. The voltage points are given in the command
parameters, which are separated by commas. Up to 20 points may be entered and the output voltage values
specified by the points will be generated in the same order as they were entered.
Command Syntax
Parameters
Default Suffix
Examples
Query Syntax
Returned Parameters
Related Commands
LIST:VOLTage <channel> <point> <NRf>
<channel>: 1 – 31, channel number
<point>: 1 – 20, point number
<NRf>: minimum to maximum voltage value of the channel
V
LIST:VOLT 1 1 2.5
LIST:VOLTage? <channel> <NR1>
<NRf>: voltage level at the point specified by the point number
LIST:VOLT:STA