Specifications

TRIGGER SUBSYSTEM
This subsystem controls the triggering of the power supply.
TRIG
This command initiates a pending level change as specified by CURR[:LEV]:TRIG or
VOLT[:LEV]:TRIG and clears the WTG bit in the Status Operation Condition register.
Command Syntax
Parameters
Examples
Query Syntax
Related Commands
TRIGger[:STARt][:IMMediate]
(None)
TRIG TRIG: IMM
(None)
ABOR; CURR:TRIG; *TRG; VOLT:TRIG
Note: The function of TRIG is similar to *TRG command except that the trigger is enabled by software in
this command, and it is enabled through hardware method in *TRG command. Most of the time, they can
be used interchangeably. But there is one exception: In parallel operation mode, due to some speed
constraints, it’s better for users to choose “TRIG” command to enable trigger instead of “*TRG
command.
TRIG:DEL
This command sets the time delay between the detection of an event on a trigger source and the start of any
corresponding trigger action on the power supply’s output.
Command Syntax
Parameters
Default Suffix
*RST Value
Examples
Query Syntax
Returned Parameters
Related Commands
TRIGger[:STARt]:DELay <channel> <NR1>
<channel>: 1 – 31, channel number
<NR1>: 0 – 32000, delay time in millisecond
ms
0
TRIG:DEL 1 1000
TRIGger[:STARt]:DELay? <channel>
<NR1> delay time in millisecond
ABOR CURR:TRIG *TRG TRIG VOLT:TRIG