Specifications
IEEE 488.1 COMMANDS AND THEIR EQUIVALENT SCPI COMMANDS
In order to comply with AMREL old PD IEEE 488.1 firmware option, some IEEE 488.1 commands are still
supported in this version. However, each IEEE 488.1 command has an equivalent SCPI command. The following
table shows the corresponding SCPI command for each IEEE 488.1 command.
IEEE 488.1 Commands and Equivalent SCPI Command:
Command Equivalent SCPI command
IOUT? <channel> MEAS:CURR? <channel>
IOUT1? MEAS:CURR? 1
IOUT2? MEAS:CURR? 2
ISET <channel> <value> CURR <channel> <value>
ISET1 <value> CURR 1 <value>
ISET2 <value> CURR 2 <value>
ISET? <channel> CURR? <channel>
ISET1? CURR? 1
ISET2? CURR? 2
OCP <channel> <bool> CURR:PROT:STAT <channel> <bool>
OCP1 <bool> CURR:PROT:STAT 1 <bool>
OCP2 <bool> CURR:PROT:STAT 2 <bool>
OUT <channel> <bool> OUTP <channel> <bool>
OUT1 <bool> OUTP 1 <bool>
OUT2 <bool> OUTP 2 <bool>
OVP <channel> <bool> VOLT:PROT:STAT <channel> <bool>
OVP1 <bool> VOLT:PROT:STAT 1 <bool>
OVP2 <bool> VOLT:PROT:STAT <bool>
OVSET <channel> <value> VOLT:PROT <channel> <value>
OVSET1 <value> VOLT:PROT 1 <value>
OVSET2 <value> VOLT:PROT 2 <value>
OVSET? <channel> VOLT:PROT? <channel>
OVSET1? VOLT:PROT? 1
OVSET2? VOLT:PROT? 2
STATUS? N / A *
VOUT? <channel> MEAS:VOLT? <channel>
VOUT1? MEAS:VOLT? 1
VOUT2? MEAS:VOLT? 2
VSET <channel> <value> VOLT <channel> <value>
VSET1 <value> VOLT 1 <value>
VEST2 <value> VOLT 2 <value>
VSET? <channel> VOLT? <channel>
VSET1? VOLT? 1
VSET2? VOLT? 2
<Note> *: For IEEE 488.1 option status reporting, please refer to 6.2 Status reporting – Non-SCPI command
status reporting part of this manual.
6-40