Specifications

INDUCTIVE LOADS
To prevent damage to the power supply from inductive kickback or back EMF from a motor, connect a surge
absorber diode across the output (parallel). The diode should be rated at greater than two times the supply’s
output voltage and have a current surge rating two times greater than the supply’s output rating. Connect the
cathode to the positive output and the anode to the negative output/return.
INDUCTIVE LOAD WITH SURGE ABSORBER PROTECTION
CONNECTING SINGLE LOADS
The single loads connection. Local sense lines shown below are the factory default connections for the rear
DC output terminal or using the internal isolation relay terminal.
You do not need remote sensing for basic operation of your supply. However, if you wish to correct any
small drops in your load lines, the remote sensing feature.
USE THE LARGEST GAUGE
AND SHORTEST LENGTH POSSIBLE
SINGLE LOAD WITH LOCAL SENSING (DEFAULT)
POWER SUPPLY
(+) Sense
(+) Output
(-) Output
(-) Sense
LOAD
(+) Input
(-) Input
POWER SUPPLY
(+) Sense
(+) Output
(-) Output
(-) Sense
INDUCTIVE LOAD
Surge Absorber
(+)
(-)
2-7