Specifications

8. Press this key to do ILIST or Current Step. Use #8 key and
#2 key to scroll up to 100 current stepping value. Use #7 key
to change current stepping value at that step. Use #9 key to
change stepping time interval at that step. Numeric key for 5.
9.
This key scrolls menu. Numeric key for 6.
10. Press this key to turn the ILIST on or off. When the output is disabled,
the LCD displays “--OUTPUT OFF--“.
11. Press this key to start and stop voltage stepping (VLIST).
Numeric key for 0.
12. Press this key to enable and disable over voltage protection. If
over voltage protection is enabled, a is indicated by OVP.
Numeric entry key for two.
13. Press this key to enable or disable over current protection. If
over current protection is enabled, a is indicated by OCP.
Numeric key for 3.
14.
Press this key to enable/disable supply output. Numeric enters for
decimal point.
15. Press this key to set the number of loop times for the voltage
and/or current stepping.
16. Press this key to do voltage step programming. Use #8 key and
#2 key to scroll up to 100 voltage step. Use #7 key to change voltage
value at that step. Use #9 key to alter time stepping interval at that step.
17. For Multi-channel PDS use to select channels
18. Enters the number keyed.
19. Encoder Digital Encoder to provide real-time programmatic control
5
ILIST
6
4
VLIST
1
ILIST ON/OFF
0
VLIST ON/OFF
2
OVP ON/OFF
3
OCP ON/OFF
z
OUT ON/OFF
FUNC
ENTER
CHANNEL
MODE
RELAY
5-4