Specifications

to scroll up to 100 current stepping value. Use #7 key to change
current stepping value at that step. Use #9 key to change stepping time
interval at that step. Numeric key for 5.
10.
High/Low range selection for constant current mode. This key also to
scrolls menu. Numeric key for 6.
10. Press this key to turn the output on or off. When the output is disabled,
the LCD displays “--OUTPUT OFF--“.
11. Press this key to start and stop voltage stepping. Numeric key for 0.
14. Press this key to enable and disable over voltage protection. If over
voltage protection is enabled, a is indicated by OVP.
Numeric entry key for 2.
15. Press this key to enable or disable over current protection. If over
current protection is enabled, a is indicated by OCP.
Numeric key for 3.
16. Press this key
to start and stop current stepping. Numeric enter
for decimal point.
15. RELAY Press this key will activate the relay menu.
16. Press this key to do voltage step programming. Use #8 key and #2 key
to scroll up to 100 voltage step. Use #7 key to change voltage value at
that step. Use #9 key to alter time stepping interval at that step.
17. PDS40-30AR only has a single channel. (Key disabled).
18. Enters the number keyed.
6
RANGE
4
VSTEP
1
OUT ON/OFF
0
VSTEP ON/OFF
2
OVP ON/OFF
3
OCP ON/OFF
z
ISTEP ON/OFF
CHANNEL
ENTER
5-18