Specifications
ENABLING / DISABLING OVER CURRENT PROTECTION
To enable the over current protection circuit, press the "OCP ON/OFF (3)" key and the OCP enunciator is
turned on. To disable the over current protection, press the "OCP ON/OFF (3)" key one more time and the
enunciator is turned off. When the VFD displays “OVER CURRENT”, the over current protection circuit has
been activated and the output is disabled. To reset, press the "OCP ON/OFF (3)" key and the enunciator
will stop blinking. To turn the output on again, press the "OCP ON/OFF (3)" key.
<NOTES:>
3.OCP IS SET BY THE VALUE OF THE CURRENT LIMIT.
4. If OCP is enabled and the constant current
Mode (CC) is activated; the power supply output is disabled.
ENABLING / DISABLING OUTPUTS
All models of the PDS series have the capability of disabling their outputs by entering a new operating
parameters or connecting / disconnecting the load. Once the modification has been completed, one can enable
the power supply to operate at the new values. The output is enabled or disabled by pressing the "OUT
ON/OFF (1)" key. To return the supply to normal operation, press the "OUT ON/OFF 1)" key again to
toggle the output on.
The PDS series output is enabled or disabled by selecting the channel/s and pressing the "OUT (ON/OFF)
(1)" key. If this is a multi-channel power supply, the channels can be selected by pressing the “ENTER” or
“CLEAR” keys.
CV
CC
OVP
OCP
1 2 3 4 5 6 7 8
° X --OUTPUT OF--
o L [1] ^_ _ _ _ _ _ _ LCL
CV
CC
OVP
OCP
1 2 3 4 5 6 7 8
° X -OVER CURRENT-
o L [1] ^_ _ _ _ _ _ _ LCL
CV
CC
OVP
OCP
1 2 3 4 5 6 7 8
° X --OUTPUT OF--
L [1] ^_ _ _ _ _ _ _ LCL
CV
CC
OVP
OCP
1 2 3 4 5 6 7 8
° X 1.000V 1.0000A
L [1] ^_ _ _ _ _ _ _ LCL
5-24