Product Overview

The FILL-TROL
®
S y s t e m
Expansion Control with Automatic Fill Feature
The AMTROL FILL-TROL
®
system consists of a specially adapted
EXTROL pre-pressurized, diaphragm-type expansion tank, and the
FILL-TROL, a specially designed, automatic, pressure-reducing fill valve.
Provides accurate system make up
Eliminates need for a separate, automatic fill valve
Fully adjustable up to a maximum working pressure of 100 psig
Factory pre-charged to 12 psig; tank pressure controls system fill
FILL-TROL Specifications
Ta n k Max. Accept. A B S y s t e m S h i p p i n g
M o d e l Vo l u m e Vo l u m e H e i g h t D i a m e t e r C o n n .
1
We i g h t
N u m b e r ( G a l l o n s ) ( G a l l o n s ) ( I n c h e s ) ( I n c h e s ) ( I n c h e s ) ( l b s . )
1 0 9 2 . 0 0 . 9 1 4
3
4
8
1
2
6
1 1 0 4 . 4 2 . 5 1 7
3
8
1 1
1
2
1 0
1 1 1 7 . 6 2 . 5 2 4
5
8
1 1
1
2
1 5
1 1 2 1 4 . 0 1 1 . 3 2 3 1 5
3
8
1
2
2 4
1 System Connection is NPFT
Note: A standard EXTROL tank is not interchangeable with a FILL-TROL tank.
To use either sizing chart on page 4 for selection, 109 FILL-TROL is equivalent to #15 EXTROL,
110 FILL-TROL is equivalent to #30 EXTROL, 111 FILL-TROL is equivalent to #60 EXTROL, and 112 FILL-TROL is
equivalent to #90 EXTROL.
FILL-TROL Combination Packages
M o d e l F I L L - T R O L P u r g e r Ve n t S h i p p i n g
N u m b e r M o d e l M o d e l M o d e l Weight (lbs.)
109-P/1 or 1
1
4
1 0 9 443 or 444 7 0 0 - C 1 0
110-P/1 or 1
1
4
1 1 0 443 or 444 7 0 0 - C 1 4
1 1 1 - P / 1
1
4
1 1 1 4 4 4 7 0 0 - C 1 8
How the FILL-TROL System Works
Water enters the FILL-TROL valve, pushing open the
check valve, and flows into the heating system. The
automatic shut-off valve is kept open by the diaphragm
pressing against the pressure plate, raising the stem of
the fill gate, which compresses the automatic shut-off
valve spring. When the heating system reaches fill
pressure (12 psig), the tank's diaphragm depresses and
the automatic shut-off valve is closed.
Whenever system pressure falls below 12 psig, the
automatic shut-off valve is pressed open by the
diaphragm. Make-up water flows into the system to
restore pressure.

Summary of content (1 pages)