9. PUMP PROTECTION AND DIAGNOSTICS
The Well-X1
®
continually monitors pressure, cycle time and voltage to protect the well pump. The following error codes
alert the user to a potential problem, prompting service.
E1: Rapid Cycle
E2: Low Suction (low water cut-off)
E3: Voltage Protection
WELL-X1
®
ERROR CODES
When an error occurs, the display will ash a diagnostic code.
ERROR CODE POSSIBLE CAUSES AND CONTROL ACTION
E1: Rapid Cycle
Multiple cycles below a safe runtime indicate an incorrect
precharge, undersized Well-X1
®
or waterlogged tank. Pump
continues to run.
E2: Low Suction
Pump operation below 10 psi indicates a low well level, well
piping leak, insufcient prime, failing pump or loose wiring.
Pump will shut down and attempt to restart every 60 minutes.
E3: Voltage Protection
If line voltage varies outside a safe operating range, low or
high, the control will run for up to two minutes to ensure water
is available, then shut the pump off until voltage is restored to a
normal range.