7. WIRING
1. Shut off the circuit breaker for the well system. Loosen
the silver screw on top of the control and remove cover
to expose the control wires.
Electrocution hazard. For your safety,
the information in this manual must be followed to
minimize the risk of electric shock, property damage
or personal injury. Properly ground to conform with all
governing codes and ordinances.
2. The 12 gauge wire leads are pre-stripped and ready
to accept standard wire nuts. Each wire is color coded
to correspond with the diagram below. Use water tight
conduit, connections, and wire nuts for an outside
application.
3. Wiring is similar to a traditional mechanical pressure
switch. Two leads are connected to line supply, while
the other supply the pump motor or starter. Wire the
control to the line supply and pump motor or pump
starter as required by the manufacturer's instructions.
It is recommended that service switch be installed in
addition to the circuit breaker. The disconnect for the
controller must break all incoming power lines. This
should interrupt line voltage and be installed near the
Well-X1
®
and labeled appropriately.
4. After completing the wiring, reattach top cover and
tighten screw. Ensure no loose wires protrude from the
control.
LINE
LINE
MOTOR
MOTOR
BLACK
WHITE/STRIPE
BLUE
WHITE
SCREW