Instructions / Assembly

Warranty
WX Models: Seven (7) Year Limited Warranty
Visit www.amtrol.com for complete warranty details and to register
the serial number of your well tank.
Start Up
Fine Tuning Procedures
Many times the actual pressure switch will vary from the standard
pressure range indicated. These variations could cause a
momentary lag of water delivery, as the pressure switch is not
tuned to the Well-X-Trol precharge pressure.
1. Fill the system and Well-X-Trol until pump cuts off.
2. Open one or more fixtures to drain the Well-X-Trol.
3. If there is a momentary pause in the water flow from the time
the Well-X-Trol is emptied and the pump starts, adjust pump
cut-in setting clockwise slightly (Figure 2).
4. Close fixtures and refill Well-X-Trol to pump cut off. Check
time to fill.
5. Open fixtures and see if pause in water is eliminated. If not,
continue adjusting pressure switch.
Adjusting Precharge After Installation
Step 1. Drain tank of all water. Check precharge pressure in
the Well-X-Trol Tank.
Step 2. Release or add air as necessary to make the recharge
pressure 2 psig below the pressure switch pump cut-in setting.
Maintenance
A qualified professional should check the complete system,
including the Well-X-Trol, yearly and more frequently as the
system ages.
Pressure Adjustment:
Clockwise to increase
cut-out pressure.
Counter-clockise to decrease
cut-out pressure.
Figure 2
1400 Division Road, West Warwick, RI 02893 USA
T: 800.426.8765 F: 800.293.1519
www.amtrol.com
© 2016 AMTROL Inc. Part #: 9016-868 MC10185 (09/16)