Instruction manual
Network Configuration
72
Instruction Manual – DXLink™ Twisted Pair Transmitters/Receiver
Tip: To monitor the ID Pushbutton boot state of a module, see the “ID Pushbutton Boot and NetLinx LED 
Behavior” table below.
ID Pushbutton Boot State and LED Behavior
To monitor the ID Pushbutton boot state of a module by its LEDs, check both the Link/Act and Status LED columns.
ID Pushbutton Boot and NetLinx LED Behavior 
ID Pushbutton Boot States Link/Act LED Status LED
Boot with ID Pushbutton held down Slow blink (1 Hz) Slow blink (1 Hz)
ID Pushbutton held down long enough for 
reset to default parameters
Fast blink until ID Pushbutton is 
released, then OFF
Fast blink until ID Pushbutton is 
released, then OFF
ID Pushbutton held down long enough for 
reset to default firmware image
Solid ON, transitions to OFF once 
the unit completes writing to flash 
and is ready to reboot
Solid ON, transitions to OFF once 
the unit completes writing to flash 
and is ready to reboot
In Auto ID mode Normal Blink (2 Hz)
ID Pushbutton held down long enough to 
accept new ID
2 blinks, then normal 2 blinks, then normal
After boot: ID Pushbutton held down, but not 
long enough for IP mode change
Slow blink (1 Hz) Slow blink (1 Hz)
After boot: ID Pushbutton held down long 
enough for IP mode change
Fast blink, then OFF Fast blink, then OFF