Instruction manual
NetLinx Programming of DXLink Transmitters and Receivers
93
Instruction Manual – DXLink™ Twisted Pair Transmitters/Receiver
Serial SEND_COMMANDs (Transmitters and Receivers), continued
RXCLR
Clear all characters in the 
receive buffer waiting to be 
sent to the Master.
Syntax: 
SEND_COMMAND <DEV>,"'RXCLR'"
Example:
SEND_COMMAND dvRXRS232,"'RXCLR'"
Clears all characters in the receive buffer waiting to be sent to the Master.
RXOFF
Disable the transmission of 
incoming received 
characters to the Master 
(default).
Syntax: 
SEND_COMMAND <DEV>,"'RXOFF'"
Example:
SEND_COMMAND dvRXRS232,"'RXOFF'"
Disables the transmission of incoming received characters to the Master.
RXON
Start transmitting received 
characters to the Master. 
Enables sending incoming 
received characters to the 
Master. 
This command is automatically sent by the Master when a 'CREATE_BUFFER' program 
instruction is executed. 
Syntax: 
SEND_COMMAND <DEV>,"'RXON'"
Example:
SEND_COMMAND dvRXRS232,"'RXON'"
Sets the RX RS-232 port to transmit received characters to the Master.
TXCLR
Stop and clear all characters 
waiting in the transmit out 
buffer and stops 
transmission.
Syntax:
SEND_COMMAND <DEV>,"'TXCLR'"
Example: 
SEND_COMMAND dvRXRS232,"'TXCLR'"
 Stops and clears all characters waiting in the RX serial port’s transmit buffer.
SET BAUD 
(shown in examples)
Or
TSET BAUD
Use either of these 
commands to set the serial 
communication parameters.
Note: The DXLink 
Transmitters and Receiver 
only support RS-232 serial 
communication. 
Note: This value is not saved in non-volatile memory and is reset to default (9600, N, 8, 1) 
at power-up.
Syntax: 
SEND_COMMAND <DEV>,"'SET BAUD <baud>,<parity>,<data>, <stop>'"
Valid responses: 
• baud = 115200, 76800, 57600, 38400, 19200, 9600, 4800, 2400, 1200, 600, 300, 150.
• parity = N (none), O (odd), E (even), M (mark), S (space)
• data = 7 or 8 data bits
• stop = 1 or 2 stop bits
Note: The only valid 9 bit combination is (baud),N,9,1.
Example:
SEND_COMMAND DEVICE_1,"'SET BAUD 115200,N,8,1'"
Sets the DEVICE_1 port’s communication parameters to 115,200 baud, no parity, 8 
data bits, and 1 stop bit.