Instruction manual

NetLinx Programming of DXLink Transmitters and Receivers
82
Instruction Manual – DXLink™ Twisted Pair Transmitters/Receiver
IR SEND_COMMANDs (Transmitters and Receivers), continued
Command Description
CH
Send IR pulses for the
selected channel.
All channels below 100 are transmitted as two digits.
If the IR code for ENTER (function #21) is loaded, an Enter will follow the
number.
If the channel is greater than or equal to (>=) 100, then IR function 127 or 20
(whichever exists) is generated for the one hundred digit.
Note: Set the Pulse and Wait times with 'CTON' and 'CTOF' (see the next page).
Syntax:
SEND_COMMAND <DEV>,"'CH',<channel number>"
Variable:
channel number = 0 to 199 channels
Example:
SEND_COMMAND IR_1,"'CH',18"
The IR port on the DXLink TX or RX performs the following:
Transmits IR signals for 1 (IR code 11).
The transmit time is set with the CTON command.
Waits until the time set with the CTOF command elapses.
Transmits IR signals for 8 (IR code 18).
Waits for the time set with the CTOF command elapses.
If the IR code for Enter (IR code 21) is programmed, the module performs the
following steps:
Transmits IR signals for Enter (IR code 21).
Waits for the time set with the CTOF command elapses.
CP
Halt and clear all active or
buffered IR commands,
and then send a single IR
pulse.
Pulse and Wait times can be set with the 'CTON' and 'CTOF' commands.
Syntax:
SEND_COMMAND <DEV>,"'CP',<code>"
Variable:
code = IR port’s channel value 0 to 252 (253 to 255 reserved).
Example:
SEND_COMMAND IR_1,"'CP',2"
Clears the active/buffered commands and pulses IR port’s channel 2.
CTOF
Set the duration of the Off
time (no signal) between IR
pulses for channel and IR
function transmissions. Off
time settings are stored in
non-volatile memory.
This command sets the delay time between pulses generated by the 'CH' or
'XCH' Send Commands in tenths of seconds.
Syntax:
SEND_COMMAND <DEV>,"'CTOF',<time>"
Variable:
time = 0 to 255. Given in 1/10th of a second increments. Default is 5
(0.5 seconds).
Example:
SEND_COMMAND IR_1,"'CTOF',10"
Sets the off time between each IR pulse to 1 second.