Integrated Master – NetLinx® Programming
155
Instruction Manual – Enova DGX 8/16/32 Digital Media Switchers
Diagnostic and Auxiliary BCS SEND_COMMANDs
Important: Only one port at a time can send or receive communication.
The commands in the table below are sent to Port 3.
Note: For information on BCS commands for diagnostic purposes, see Appendix D on page 199.
SEND_COMMANDs – Basic BCS Commands (continued)
SL<L#>I<I#>T
(input status)
or
SL<L#>O<O#>T
(output status)
Returns connection status.
(To verify status on the
default level, omit L<L#>.)
Syntax:
SEND_COMMAND <Device:Port:System>,"'SL<L#>I<I#>T'"
or
SEND_COMMAND <Device:Port:System>,"'SL<L#>O<O#>T'"
Note: The “Device” number is assigned by the integrated NetLinx Master.
Variables:
L# = level number (virtual matrix number) either 0 or 1 (both switch video
along with any embedded audio)
I# = input port number (for Enova DGX 8: 1-8 = Inputs 1-8,
Enova DGX 16: 1-16 = Inputs 1-16, Enova DGX 32: 1-32 = Inputs 1-32)
O# = output port number (for Enova DGX 8: 1-8 = Outputs 1-8,
Enova DGX 16: 1-16 = Outputs 1-16, Enova DGX 32: 1-32 = Outputs 1-32)
Example 1:
SEND_COMMAND 5002:2:0,"'SL0I3T'"
Returns which outputs are connected to Input 3 on Level 0 (Virtual Matrix 0).
Example 2:
SEND_COMMAND 5002:2:0,"'SL0O25T'"
Returns which input is connected to Output 25 on Level 0 (Virtual Matrix 0).
Response is of the form:
SL<L#>I<I#>T(0#) or SL<L#>O<O#>T(I#)
or the parentheses will be empty ( ) if a connection is not present
For example: SL0I3T(4 7 16) shows that Outputs 4, 7, and 16 are
connected to Input 3 on Level 0 (Virtual Matrix 0).
SEND_COMMANDs – Diagnostic and Auxiliary BCS Commands
Command Description
~scri<i#>v<v#>!
Diagnostic – Requests a level
of detailed diagnostic infor-
mation for all or one of seven
system components.
Syntax:
SEND_COMMAND <Device:Port:System>,"'~scri<i#>v<v#>!'"
Note: The “Device” number is assigned by the integrated NetLinx Master.
Variables:
i# = identity number 0-7 (use 0 for all components; 1-7 specify individual
components)
v# = verbosity number 0-3 (specifies level of detail from 0 the lowest level to
3 the highest level)
Example:
SEND_COMMAND 5002:3:0,"'~scri6v3!'"
Requests the highest level of detail on the power system.