Instruction manual

Overview and General Specifications
12
Epica DGX 16 and Epica DGX 32 Instruction Manual
Power Supply Units
Each of the power supply units on the rear of the enclosure (FIG. 5) has a power receptacle that will
accept all major international standard power sources. (US power cords are included with all shipments
unless ordered otherwise.) Maximum power specifications are provided on the power supply
receptacles.
For information on applying power, see page 36.
The power supply unit has three LED indicators (in order from left to right):
AC ( ): When the LED is green, the power is good.
DC ( ): When the LED is green, the power is good.
Temperature ( ): When the LED is not illuminated, the temperature is good; when the LED
is amber, the temperature is above normal.
Caution: Each power supply has a small toggle switch to the left of its LEDs that controls internal
power and must remain flipped to the right
for the system to operate. Do not flip this switch to the left.
Input and Output Boards
A single enclosure can handle a combination of signals: the DVI boards support DVI-D signals, and the
SC Optical boards support DVI-D, analog video,* and digital or analog stereo audio signals. All signals
are automatically converted to the output device’s format, with DGX Fiber Modules used in the
conversion process for the DGX SC Optical boards.
* Supported analog video signals include RGBHV, RGBS, RGsB, and Y/Pb/Pr.
Epica DGX 16
Epica DGX 16 enclosures have 8 horizontal board slots (4 slots each for input and output boards with
four connectors each), allowing for a maximum configuration of 16x16.
FIG. 5 Power supply receptacles, LEDs, and switches
FIG. 6 DGX DVI and DGX SC Optical Input and Output Boards
3 Indicator LEDs
Leave switch on
(flipped right)
Input boards Output boards
DGX DVI Board
DGX SC Optical Board