Instruction manual

Installation and Setup
32
Epica DGX 16 and Epica DGX 32 Instruction Manual
Connecting Serial Controller to USB Port
Controlling an Epica DGX 16 or 32 using a USB connection requires the creation of a virtual Com port.
Once created, the virtual Com port is used as if it were a standard serial connection and can connect to a
control application (such as, APControl 3.0) or to a terminal emulation program (e.g., Windows
®
HyperTerminal) for BCS control.
Important: You must have adequate rights to install USB device drivers to the PC. Check with your
System Administrator to be sure you have the required access.
When establishing a new connection, complete all of the steps in the instructions starting below.
Or
When reconnecting after previously establishing a USB connection, complete Steps 1 and 2 and then
set up and run the desired software program or utility.
The following steps apply when you use the AMX AutoPatch CD that shipped with the system. Using the
default selections, the Found New Hardware Wizard searches and installs the software.
Note: If for any reason the Wizard does not automatically install the software, APBridge.inf is located
on the AMX AutoPatch CD (<CDDrive>:\Configuration\APConfig\USB) and at www.amx.com (enter
APBridge.inf in the Search AMX.com field in the upper right-hand corner of the site).
To attach a PC to the USB (mini-B) port and establish a virtual Com port:
1.
Apply power to the enclosure (see page 36).
2. Connect the enclosure to a PC running Windows using the USB cable provided by AMX (FIG. 19).
3. If establishing a new connection, complete the remaining steps.
Or
If reconnecting after previously establishing a USB connection, go to Step 5 of the procedure for
identifying the virtual Com port on page 34 to run the desired software.
Note: The following dialog boxes appear only during the initial USB connection. Once the virtual
Com port has been assigned to the enclosure, the dialog boxes do not appear again. If they do
appear, you have connected the USB plug to a different Com port than the initial one either switch
to the initial Com port or establish a virtual Com port for the new port on the PC.
The Found New Hardware notice window appears briefly. The Hardware Wizard will refer to the
virtual Com port used by the Epica DGX 16 or 32 as an “AutoPatch USB Bridge” or “USB Device.”
FIG. 19 USB cable connected to USB port on Epica DGX 32 and to PC
USB cable to PC
USB (mini-B) port
Virtual Com port