The RS-232 factory default communications settings are: 9600 baud, No Parity, 8 bits, and 1 stop
bit. The following table lists the RS-232 Port DB-9 (male) pinouts.
The following table lists the RS-232 DIP switch settings.
Setting the AXlink Device DIP switch (S5)
The eight-position Device DIP switch (S5), shown in FIG. 5, must match the number assigned in
the Axcess software program. The Device DIP switch example is set to 90 (2 + 8 + 16 + 64 = 90),
the factory default setting.
RS-232 Port DB-9 (male) Pinouts
Pin Signal Function
1N/AN/A
2RXDRXD
3TXDTXD
4N/AN/A
5GNDGND
6N/AN/A
7RTSRTS
8CTSCTS
9N/AN/A
RS-232 DIP Switch (S2) Settings
Position 1 2 3 4 5 6 7 8
Function Stop Bits Data Bits Parity Baud Rates
Off Off Off Off Off Off Off Off
2 bits 7 bits Unused 300
On On On Off Off On Off Off
1 bit 8 bits Unused 600
Off On Off Off On Off
Unused 1,200
On On Off On On Off
Unused 2,400
Off Off On Off Off On
Unused 4,800
On Off On On Off On
Even 9,600
Off On On Off On On
Odd 19,200
On On On On On On
None 38,400
FIG. 5 AXlink device DIP switch (S5) (default value of 90)
AXlink
DIP switch
(S5)
1 2 3 4 5 6 7 8