Specifications

IN - 4 Installation Ver. 0002
IN.2 INTER-MODULAR CONNECTION
IN.2.1 POWER BUS CONNECTION
Use 2 of the 3 plates and the washers and nuts supplied with each module to make the
connection of the Power bus (lower part of the module). All the modules must be tightly
joined to each other guaranteeing a good electrical contact. The tightening torque must be
between 2.3 and 2.8 Nm. These plates are identical and no particular order or direction
has to be observed.
The Power Supply module must provide the power needed by all the drives connected to it. If
the power required by the group of motors exceeds the maximum that a single power supply
can provide, two power supplies must be used assigning to each one the supply of a separate
group of drives.
The Power Buses of different Power Supply Modules must NEVER be
connected in parallel.
Always make separate groups, connecting each Power Supply to a
different group of drives.
X Axis Drive
POWER
SUPPLY
(A)
Spindle Drive
System (A) System (B)
POWER
SUPPLY
(B)
Y Axis Drive
Z Axis Drive
W Axis Drive