Specifications

IN - 14 Installation Ver. 0002
IN.3.2.1 GUIDE FOR SELECTING THE POWER CABLES OF THE MOTORS
The following tables serve as guides for selecting the power cables of the synchronous
motors (FXM) and of the asynchronous motors (SPM).
They show the right cable section for each motor.
They meet the European directive and the mechanical compatibility with the drive and motor
connectors.
(A) In these cases, do not use the angled socket -AMC- .
(O) In order to meet regulations on current density, these cables must not be run in channels.
Rated
Current
(Amp)
1.5 mm
2
2.5 mm
2
FXM11.20A.xx.xx0 0,3
FXM11.30A.xx.xx0 0,4
FXM11.40A.xx.xx0 0,5
FXM12.20A.xx.xx0 0,5
FXM12.30A.xx.xx0 0,8
FXM12.40A.xx.xx0 1,0
FXM13.20A.xx.xx0 0,8
FXM13.30A.xx.xx0 1,1
FXM13.40A.xx.xx0 1,5
FXM14.20A.xx.xx0 1,0
FXM14.30A.xx.xx0 1,6
FXM14.40A.xx.xx0 2,0
FXM31.20A.xx.xx0 0,8
FXM31.30A.xx.xx0 1,1
FXM31.40A.xx.xx0 1,5
FXM32.20A.xx.xx0 1,5
FXM32.30A.xx.xx0 2,3
FXM32.40A.xx.xx0 3,1
FXM33.20A.xx.xx0 2,3
FXM33.30A.xx.xx0 3,5
FXM33.40A.xx.xx0 4,6
FXM34.20A.xx.xx0 3,1
FXM34.30A.xx.xx0 4,7
FXM34.40A.xx.xx0 6,2
FXM53.12A.xx.xx0 2,4
FXM53.20A.xx.xx0 4,0
FXM53.30A.xx.xx0 6,0
FXM53.40A.xx.xx0 8,0
FXM54.12A.xx.xx0 3,2
FXM54.20A.xx.xx0 5,5
Best Option
Rated
Current
(Amp)
1.5 mm
2
2.5 mm
2
4 mm
2
6 mm
2
10 mm
2
FXM54.30A.xx.xx0 8,1
FXM54.40A.xx.xx0 10,2
FXM55.12A.xx.xx0 4,0
FXM55.20A.xx.xx0 6,8
FXM55.30A.xx.xx0 10,2
FXM55.40A.xx.xx0 13,3
FXM73.12A.xx.xx0 4,7
FXM73.20A.xx.xx0 7,8
FXM73.30A.xx.xx0 11,3
FXM73.40A.xx.xx0 15,4
FXM74.12A.xx.xx0 6,2
FXM74.20A.xx.xx0 10,4
FXM74.30A.xx.xx0 15,4
FXM74.40A.xx.xx0 20,6
A
FXM75.12A.xx.xx0 7,7
FXM75.20A.xx.xx0 12,9
FXM75.30A.xx.xx0 19,3
A
FXM75.40A.xx.xx0 (*) 25,3
FXM76.12A.xx.xx0 9,3
FXM76.20A.xx.xx0 15,4
FXM76.30A.xx.xx0 22,6
A
FXM76.40A.xx.xx0 (*) 31,0
FXM77.12A.xx.xx0 10,9
FXM77.20A.xx.xx0 17,3
A
FXM77.30A.xx.xx0 (*) 26,5
FXM77.40A.xx.xx0 (*) 35,7
FXM78.12A.xx.xx0 12,5
FXM78.20A.xx.xx0 20,6
A
FXM78.30A.xx.xx0 (*) 31,0
FXM78.40A.xx.xx0 (*) 41,2
O
(*) MC 46 Valid Options