Specifications

Parameters, Variables and Commands Ver. 0002 A - 13
CV1 s (F309) CurrentUFeedback
CV2 s (F310) CurrentVFeedback
Function: Display of the feedback value of the U / V current.
Valid values: -200..200 Amperes (instantaneous values).
CV3 (F311) CurrentFeedback
Function: Display of the motor rms current.
Valid values: -200..200 Amperes rms
CV10 Fs (F305) CurrentUOffset
CV11 Fs (F306) CurrentVOffset
Function: Current feedback offset compensation for the U / V phase.
Valid values: -5000..5000 (depends on the Drive connected)
Default value: 0, This value is factory measured and adjusted.
4. DIAGNOSTICS GROUP “D”
DP1 O (F400) ErrorsDisables
Function: Using 13 32-bit, it registers the possible disabling of each error. This parameter may
be modified through variables DV15 -F2101- and DV16 -F2102-.
DP142 O (S142) ApplicationType
Function: For information only. It contains the type of application the Drive is being used for
(e.g. spindle, rotary axis, etc.)
DV1 (S11) Class1Diagnostics (Errors)
Function: The DV1 variable contains the numeric data which in 16-bit binary code represents
the error status according to the table below. Bit (from MSB to LSB) name, code at
front display of the module.
Bit Name Error
————————————————————————————-
15 (MSB) ManufacturerSpecificError Rest.
14 Class1Reserved
13 TravelLimit
12 ComunicationError 400->499
11 ExcessivePositionDeviation 205
10 PowerSupplyPhaseError
9 UndervoltageError 307
8 OvervoltageError 304,306
7 OvercurrentError 212
6 ErrorInElectronicCommutationSystem 213->214
5 FeedbackError 600->699
4 ControlVoltageError 100->105
3 CoolingErrorShutdown 106
2 MotorOvertempShutdown 108
1 AmplifierOvertempShutdown 107
0 (LSB) OverloadShutdown 201, 202, 203
Bit = 0 no error
Bit = 1 error
Example: DV1 = 32804 same as 1000000000100100 in binary. Therefore, there is
FeedbackError, a MotorOvertempShutdown, and another one of the
manufacturerSpecificError type
Version: Available from version 02.01 on.