Specifications

A - 18 Parameters, Variables and Commands Ver. 0002
6. FLUX GROUP ā€œFā€
FP1 OMA (F600) MotorFluxProportionalGain
FP2 OMA (F601) MotorFluxIntegralTime
FP20 OMA (F602) MotorBEMFProportionalGain
FP21 OMA (F603) MotorBEMFIntegralTime
Function : Value of the proportional / integral action of the PI for flux and Back EMF.
Valid values: 0..32000
Default value: 0
FP30 FMA (F604) MotorInductance1
FP31 FMA (F605) MotorInductance2
FP32 FMA (F606) MotorInductance3
FP33 FMA (F607) MotorInductance4
FP34 FMA (F608) MotorInductance5
FP35 FMA (F609) MotorInductance6
FP36 FMA (F610) MotorInductance7
FP37 FMA (F611) MotorInductance8
FP38 FMA (F612) MotorInductance9
Function: Values of the magnetic saturation curve of the stator iron.
Valid values: 0.1 .. 10%
Default value: 1%
FP40.# FMA (F613.#) FluxReduction
Function: Indicates the percentage of magnetizing current that circulates through the motor
when applying load. It reduces the amount of motor noise and its overheating when
turning without load. To cancel the effect of this parameter, set it to 100%.
Valid values: 1 .. 100%
Default value: 100%
7. GENERAL GROUP ā€œGā€
GP1 O (F700) PwmFrequency
Function: Selects the communications frequency of the IGBTs.
Units: KHz
Valid values: 4 ( by default on Asynchronous motors)
8 ( by default on Synchronous motors)
GP2 O (F701) Feedback1Type
Function: Type of motor feedback.
Valid values: 0- Sinewave encoder 1-Resolver 2-Squarewave encoder, TTL
5-Heidenhain encoder (ERN 1387) for Siemens motors, 1FT6 family
Default value: 0-Sinewave encoder
t
Drive Enable
Function
Speed Enable
Function
GP3
Torque "ON"
t
t