Specifications

Parameters, Variables and Commands Ver. 0002 A - 31
13. ANALOG AND DIGITAL OUTPUT GROUP “O”
OP1 *O (F1400) DA1IDN
OP2 *O (F1401) DA2IDN
Function: They identify the internal analog variables of the Drive which will be reflected at the
electrical outputs and will be affected by the OP3 and OP4 gains respectively.
Channel 1 (pins10-11 of X7) and channel 2 (pins 8-9 of X7).
Assign a "0" value to OP1 and 7 or OP2 to allow forcing the value of the electrical
signals by means of OV1 and/or OV2.
Valid values: Name of any variable or parameter.
Default values: SV1 in the case of OP1, and SV2 in the case of OP2.
OP3 *O (F1402) DA1ValuePer10Volt
OP4 *O (F1403) DA2ValuePer10Volt
Function: They define the gains of channel 1 (pins 10-11 of X7) and channel 2 (pins 8-9 of X7).
These gains are given through the value of the variable corresponding to an output of
10 V.
Units: Those of the variable being displayed.
Valid values: 1..65535
Default value: 1000
Example: If OP1=SV2 (VelocityFeedback, in rpm) and OP3=3000. This means that when SV2 =
3000 rpm. The analog voltage will be 10 V (pins 10-11 of X7). It will maintain this rpm/
Volt ratio for the full range of ±10V.
OP5 O (F291) Prog_OutIDN
Function: Identifies the boolean variable which will be reflected at the digital output Prog_OUT
of the Compact Drive (pins 8-9 of connector X2).
Default value: 0 (not assigned), In that situation, Prog_OUT may be forced with OV5.
Example: OP5 = TV100 (the contact is closed when there is torque)
Version: Operational from version 02.03 on.
X7(11)
X7(10)
X7(9)
X7(8)
Variable examples for OP1 and OP2
SV2 -S00040-
VelocityFeedback
SV7 -F01612-
VelocityCommandFinal
TV1 -S00080-
TorqueCommand
TV2 -S00084-
TorqueFeedback
CV3 -F00311-
CurrentFeedback
.... and more
Physical Analog Outputs
D/A
OP1 -F01400-
DA1IDN
OP3 -F01402-
DA1ValuePer10Volts
Ref
±10 Volts
max.
OP2 -F01401-
DA2IDN
OP4 -F01403-
DA2ValuePer10Volts
OV1 -F01408-
DA1Value
OV2 -F01409-
DA2Value
Channel 1
Channel 2
D/A
Ref
1
13
1
11
X7
P2
P1
(Phoenix,
3.5mm)
X6
(Phoenix,
3.5mm)
OP5 -F01411-
Prog_OutIDN
X2(8)
X2(9)
OV5 -F01412-
Prog_Out
Physical Digital Output (Compact Drive)
X2
1
10
(Phoenix,
3.5mm)