Specifications

9 | P a g e
2.6.6 Touch Displays
All touch interfaces shall be incorporated into the display unit; overlays are not acceptable
for performing touch interaction. Touch displays are to be specified in the design phase of a
project.
2.7 Switching and Control Standards
2.7.1 Controllers
Control equipment is exclusively AMX unless otherwise specified by ISTS. Should a design
require a control product not able to be supplied by AMX any variation shall not be
accepted unless written permission with relevant data sheet is supplied to ISTS before
installation.
For small tutorial room style spaces ISTS recommends the AMX integrated control pad as
the sole control device. For larger spaces with more complex control requirements ISTS
recommends an AMX NetLinx Integrated Controller with either a slave keypad or AMX touch
screen panel. The AMX Enova is suitable as a room control device, as it contains a NetLinx
Integrated Controller. All AMX controllers must be networked and capable of integration
with the University’s AMX RMS system.
2.7.2 Switching
The University utilizes Extron switching equipment for typical spaces, alternatively utilising AMX
Enova all-in-one solutions as required to meet design goals. Any space that has been designated to
be converted from analogue to digital, or any space that is designated to be configured to output
High Definition, shall require the use of a High Definition Digital HDMI switcher/matrix. The switcher
shall be capable of:
HDCP compliance with full key management on all inputs and outputs.
EDID management
Scaling/frame rate conversion
HDMI Audio embedding and de-embedding
1920x1200@60Hz
Colour Space management
Any variations, such as for spaces that require more switching capability that can be provided
through a listed solution, must be approved by ISTS before the commencement of works.