Specifications

Mio Modero IR
15
Mio Modero Device Family
AxLink Data and Power Connections
The Mio Modero IR uses a four-pin mini AxLink connector for power and data.
Connect the control system's AxLink connector to the AxLink connector on the rear panel of the Mio Modero
IR for data and 12 VDC power as shown in FIG. 14.
For wire prepartaion guidelines, refer to Preparing captive wires section on page 8.
Checking AxLink Status
The AxLink LED, shown in FIG. 12, lights to indicate AxLink power/data status as follows:
If the LED is on and not flashing, disconnect the AxLink connector and recheck all AxLink connections.
Then, reconnect the AxLink connector to the panel and verify the LED is flashing once per second.
Mounting Procedure
FIG. 15 shows the wallbox mounting dimensions for the Mio Modero IR.
AMX recommends mounting the Mio Modero IR in a standard one-gang wallbox, a conduit box per NEC
specs section 370, with a minimum internal clearance of 2-5/8" x 1-3/4" x 1-5/8" (HWD).
FIG. 14 AxLink straight-thru wiring
1 blink per second Indicates power is active and AxLink communication is working.
2 blinks per second Indicates the devices specified in the Master program do not match the
devices found.
3 blinks per second Indicates AxLink communication error.
Full On Indicates the following conditions:
There is no AxLink control or activity, but power is On.
The Axcess program is not loaded.
FIG. 15
Mio Modero IR mounting dimensions
PWR +
AXP
AXM
GND -
PWR +
AXP
AXM
GND -
Mio Modero Control System
2.250
[57.2 MM]
[83.4 MM]
3.282
[50.8 MM]
2.000