NI-2100 Specifications
Dimensions (HWD): 3.47" x 17.00" x 3.47" (8.81 cm x 43.18 cm x 8.82 cm)
2 rack units high
Power Requirement: 700 mA @ 12 VDC
Memory: 64 MB SDRAM
1 MB Non-volatile (NV) SRAM
Compact Flash: 128 MB or more - Upgradeable (see Other AMX Equipment)
Note: AMX may increase Flash size at any time in response to
market availability (refer to product’s online catalog page for current Compact
Flash size provided).
Weight: 4.50 lbs (2.04 kg)
Enclosure: Metal with black matte finish
Certifications: FCC Part 15 Class B, CE, and IEC 60950
Front Panel LEDs:
LINK/ACT: Green LED blinks when the Ethernet cables are connected and
terminated correctly. Also blinks when receiving Ethernet data
packets.
Status: Green LED blinks to indicate that the system is programmed and communi-
cating properly.
Output: Red LED blinks when the Controller transmits data, sets channels On and
Off, sends data strings, etc.
Input: Yellow LED blinks when the Controller receives data from button pushes,
strings, commands, channel levels, etc.
RS-232/422/485: 3 sets of red and yellow LEDs light to indicate that DB9 Ports 1 - 3 are trans-
mitting or receiving RS-232, 422, or 485 data.
Relay: 4 red LEDs light to indicate the relay channels 1 - 4 are active (closed).
These LEDs reflect the state of the relay on Port 4.
IR/Serial: 4 red LEDs light to indicate the IR/Serial channels 1 - 4 are
transmitting control data on Ports 5 - 8. LED indictor for each IR port remains
lit for the length of time that IR/Serial data is being generated.
I/O: 4 yellow LEDs light when the I/O channels 1 - 4 are active. The LED for each
I/O port reflects the state of that particular port.
Rear Panel Components:
RS-232/422/485 (Ports 1 - 3): 3 RS-232/422/485 control ports using DB9 (male) connectors with XON/
XOFF (transmit on/transmit off), CTS/RTS (clear to send/ready to send), and
300-115,200 baud.
ICSNet: 2 RJ-45 connectors for ICSNet interface (provided by optional
ICSNet daughter card).
ICSHub Out: RJ-45 connector provides data to a Hub connected to the Controller (pro-
vided by optional ICSNet daughter card).
Relay (Port 4): Four-channel single-pole single-throw relay ports
Each relay is independently controlled.
Supports up to 4 independent external relay devices
Channel range = 1-4
Each relay can switch up to 24 VDC or 28 VAC @ 1 A
8-pin 3.5 mm mini-Phoenix (female) connector provides relay termination
Digital I/O (Port 9): 4-channel binary I/O port for contact closure with each input being capable of
voltage sensing. Input format is software selectable with interactive power