Lutron® integration protocol
NOTES
1.
2.
Fade is not available for blinds since they move at a constant rate. The parameter must be entered but is ignored.
3. Fractional seconds “SS.ss” will be rounded down to the nearest quarter second. For example, if a delay time
is specified as 1.45 seconds a value of 1.25 seconds will be used.
4. The Delay time is optional. When not used, the system will use a zero second delay. The minimum delay time
is 0.25 seconds. The maximum delay time is 4 hours. Not supported in QS Standalone.
5. The system will report the target lift level and target tilt level of a Venetian blind. The actual levels are not
transmitted while it is moving.
Example: If the Kitchen Venetian (Integration ID 1) is set at 25% lift and 75% tilt, and is commanded to
go to 100% lift and 50% tilt by sending #OUTPUT,1,10,100,50 the response from the system will be
~OUTPUT,1,10,100.00,50.00