Specifications

Programming
112
NXD-430/435/435P 4.3” Wall/Flush Mount Touch Panels
Panel Runtime Operation Commands (Cont.)
@AKP Pop up the keypad icon and initialize the text string to that specified.
Keypad string is set to null on power up and is stored until power is lost.
The Prompt Text is optional.
Syntax:
"'@AKP-<initial text>;<prompt text>'"
Variables:
initial text = 1 - 50 ASCII characters.
prompt text = 1 - 50 ASCII characters.
Example:
SEND COMMAND Panel,"'@AKP-12345678;ENTER PASSWORD'"
Pops up the Keypad and initializes the text string '12345678' with prompt text ’ENTER
PASSWORD’.
@AKR Remove keyboard or keypad that was displayed using 'AKEYB', 'AKEYP', 'PKEYP',
@AKB, @AKP, @PKP, @EKP, or @TKP commands.
Syntax:
"'@AKR'"
Example:
SEND COMMAND Panel,"'@AKR'"
Removes the Keyboard/Keypad.
BEEP Output a beep.
Syntax:
"'BEEP'"
Example:
SEND COMMAND Panel,"'BEEP'"
Outputs a beep.
BRIT Set the panel brightness.
Syntax:
"'BRIT-<brightness level>'"
Variable:
brightness level = 0 - 100.
Example:
SEND COMMAND Panel,"'BRIT-50'"
Sets the brightness level to 50.
@BRT Set the panel brightness.
Syntax:
"'@BRT-<brightness level>'"
Variable:
brightness level = 0 - 100.
Example:
SEND COMMAND Panel,"'@BRT-70'"
Sets the brightness level to 70.
DBEEP Output a double beep.
Syntax:
"'DBEEP'"
Example:
SEND COMMAND Panel,"'DBEEP'"
Outputs a double beep.