NXD-430/435/435P 4.3” Wall/Flush Mount Touch Panels
Installing an NXD-430 or NXD-435 into a Rack Mount Kit (NXA-RK5)
The NXA-RK5 is a 19" (48.26 cm) wide metal rack-mount (with black matte finish) measuring 3 rack units
high.
1. Remove the faceplate from the touch panel.
2. Disconnect the capacitive touch connector from the 10-pin male plug on the faceplate.
3. Thread the incoming Ethernet and USB wiring from their terminal sources through the surface opening,
leaving enough slack in the wiring to accommodate any re-positioning of the panel.
4. Connect all data and power wiring connectors to their corresponding locations along the left side of the
device.
The USB connectors can be from either a USB extension cable or a wireless USB RF transmitter.
5. Test the incoming wiring by connecting the panel connections to their terminal locations.
Verify that the panel is receiving power from the PoE Injector and functioning properly.
6. Carefully insert the device into the NXA-RK5.
7. Secure the panel to the NXA-RK5 mount by first inserting and then tightening the three included #4-40
screws.
8. Insert the NXA-RK5 (with the connected NXD-430 unit) into the equipment rack, making sure to align
the screw holes along the sides on the NXA-RK5 with the holes in the equipment rack.
9. Use a grounded Phillips-head screwdriver to secure the NXA-RK5 to the equipment rack using the
included #10-32 screws.
10. Reconnect the capacitive touch connector to the 10-pin plug on the faceplate.
11. Place the faceplate back onto the main device.
12. Reconnect the terminal Ethernet and USB wiring to their respective terminal locations on the Ethernet
port or NetLinx Master.
Do not disconnect the connectors from the touch panel. The unit must be installed
with the necessary connectors before being inserted into the equipment rack.