Datasheet

PAGE: 3 OF 20
(a) (b)
(Note 4) When using the MSB=0 command, a Status Read must be performed.
If a status check is not carried out, the T6963C cannot operate normally, even after a delay
time.
The hardware interrupt occurs during the address calculation period (at the end of each
line).
If a MSB=0 command is sent to the T6963C during this period, the T6963C enters Wait
status.
If a status check is not carried out in this state before the next command is sent, there is the
possibility that the command or data date will not be received.
(2) Setting date
When using the T6963C, first set the data, then set the command.
Procedure for sending a command
(a)The case of 1 date (b)The case of 2 data
(Note) When sending more than two data, the last datum (or last two data) is valid.
T6963C or equ.
driven 240X128 DOTS GRAPHIC MODULES