Datasheet
AD712
Rev. G | Page 4 of 20
AD712J/A/S AD712K
Parameter Min Typ Max Min Typ Max Unit
INPUT CURRENT NOISE 0.01 0.01 pA/√Hz
OPEN-LOOP GAIN
150
400
200
400 V/mV
100/100/100
100
V/mV
OUTPUT CHARACTERISTICS
Voltage
+13, −12.5
+13.9, −13.3
+13, −12.5
+13.9, −13.3 V
±12/±12/±12
+13.8, −13.1
±12
+13.8, −13.1 V
Current +25 +25 mA
POWER SUPPLY
Rated Performance ±15 ±15 V
Operating Range
±4.5
±18 ±4.5
±18
V
Quiescent Current
+5.0
+6.8
+5.0
+6.0
mA
1
Input offset voltage specifications are guaranteed after 5 minutes of operation at T
A
= 25°C.
2
Bias current specifications are guaranteed maximum at either input after 5 minutes of operation at T
A
= 25°C. For higher temperatures, the current doubles every 10°C.
3
Defined as voltage between inputs, such that neither exceeds ±10 V from ground.
4
Typically exceeding −14.1 V negative common-mode voltage on either input results in an output phase reversal.