Datasheet

AD9553
Rev. A | Page 5 of 44
VCO CHARACTERISTICS
Table 6.
Parameter Min Typ Max Unit Test Conditions/Comments
FREQUENCY RANGE 3350 4050 MHz
VCO GAIN 45 MHz/V
VCO TRACKING RANGE ±300 ppm
VCO CALIBRATION TIME As measured from completion of the VCO calibration command
(the rising edge of
CS
(Pin 12)) until the rising edge of LOCKED (Pin 20)
Low Bandwidth Setting (170 Hz) Applies for Pin A3 to Pin A0 = 0001 to 1100, or for Pin A3 to
Pin A0 = 1111
13.3 kHz PFD Frequency 214 ms
16 kHz PFD Frequency 176 ms
Medium Bandwidth Setting (20 kHz) Applies for Pin A3 to Pin A0 = 1110 and Pin Y5 to Pin Y0 = 111111
1.5625 MHz PFD Frequency 1.82 ms
High Bandwidth Setting (75 kHz) Applies for Pin A3 to Pin A0 = 1101 to 1110
2.64 MHz PFD Frequency 1.46 ms
4.86 MHz PFD Frequency 0.80 ms
PLL LOCK TIME Using the pin selected frequency settings; lock time is from the
rising edge of the
RESET
pin to the rising edge of the LOCKED pin
Low Bandwidth Setting (170 Hz) Applies for Pin A3 to Pin A0 = 0001 to 1100 or for Pin A3 to
Pin A0 = 1111
13.3 kHz PFD Frequency 214 ms
16 kHz PFD Frequency 176 ms
Medium Bandwidth Setting (20 kHz) Applies for Pin A3 to Pin A0 = 1110 and Pin Y5 to Pin Y0 = 111111
1.5625 MHz PFD Frequency 2 ms
High Bandwidth Setting (75 kHz) Applies for Pin A3 to Pin A0 = 1101 to 1110
2.64 MHz PFD Frequency 1.50 ms
4.86 MHz PFD Frequency 0.89 ms
CRYSTAL INPUT CHARACTERISTICS
Table 7.
Parameter Min Typ Max Unit Test Conditions/Comments
CRYSTAL FREQUENCY
Range 10 25 52 MHz When using the pin selected frequency settings, the device
requires a 25 MHz crystal to support holdover functionality
Tolerance 20 ppm
CRYSTAL MOTIONAL RESISTANCE 100 Ω
CRYSTAL LOAD CAPACITANCE 10 pF Using a crystal with a specified load capacitance other than 10 pF
(8 pF to 24 pF) is possible, but necessitates using the SPI port to
alter the default register values for load capacitance