DIGITAL PLL
Table 12.
Parameter Min Typ Max Unit Test Conditions/Comments
DIGITAL PLL
Phase-Frequency Detector (PFD)
Input Frequency Range
2 100 kHz
Loop Bandwidth 0.1 2000 Hz Programmable design parameter
Phase Margin
30 89 Degrees Programmable design parameter
Closed-Loop Peaking <0.1 dB Programmable design parameter; part can be
programmed for <0.1 dB peaking in accordance with
Telcordia GR-253 jitter transfer
Reference Input (R) Division Factor
1 2
20
1, 2, …, 1,048,576
Integer Feedback (N1) Division Factor 180 2
17
180, 181, …, 131,072
Fractional Feedback Divide Ratio
0 0.999 Maximum value: 16,777,215/16,777,216
DIGITAL PLL LOCK DETECTION
Table 13.
Parameter
Min
Typ
Max
Unit
Test Conditions/Comments
PHASE LOCK DETECTOR
Threshold Programming Range
0.001 65.5 ns
Threshold Resolution 1 ps
FREQUENCY LOCK DETECTOR
Threshold Programming Range 0.001 16,700 ns Reference-to-feedback period difference
Threshold Resolution
1 ps
HOLDOVER SPECIFICATIONS
Table 14.
Parameter Min Typ Max Unit Test Conditions/Comments
HOLDOVER SPECIFICATIONS
Initial Frequency Accuracy
<0.01 ppm Excludes frequency drift of SYSCLK source; excludes
frequency drift of input reference prior to entering
holdover; compliant with GR-1244 Stratum 3