Datasheet
AD9775
Rev. E | Page 46 of 56
SIGNAL GENERATOR
CLK+/CLK–DATACLK
LECROY
PULSE
GENERATOR
TRIG
INP
AWG2021
OR
DG2020
INPUT CLOCK
DAC1, DB13–DB0
AD9775
DAC2, DB13–DB0
40-PIN RIBBON CABLE
JUMPER CONFIGURATION FOR TWO-PORT MODE PLL OFF
JP1 –
JP2 –
JP3 –
JP5 –
JP6 –
JP12 –
JP24 –
JP25 –
JP26 –
JP27 –
JP31 –
JP32 –
JP33 –
SOLDERED/IN
×
×
×
×
×
UNSOLDERED/OUT
×
×
×
×
×
×
×
×
02858-103
NOTES
1. TO USE PECL CLOCK DRIVER, SOLDER JP41 AND JP42 AND REMOVE TRANSFORMER T1.
2. IN TWO-PORT MODE, IF DATACLK/PLL_LOCK IS PROGRAMMED TO OUTPUT PIN 8, JP25
AND JP39 SHOULD BE SOLDERED. IF DATACLK/PLL_LOCK IS PROGRAMMED TO OUTPUT
PIN 53, JP46 AND JP47 SHOULD BE SOLDERED. SEE THE TWO-PORT DATA INPUT MODE
FOR MORE INFORMATION.
Figure 103. Test Configuration for AD9775 in Two-Port Mode with PLL Disabled, DAC Output Data Rate = Signal Generator Frequency,
DATACLK = Signal Generator Frequency/Interpolation Rate
SIGNAL GENERATOR
CLK+/CLK–ONEPORTCLK
LECROY
PULSE
GENERATOR
TRIG
INP
AWG2021
OR
DG2020
INPUT CLOCK
DAC1, DB13–DB0
AD9775
DAC2, DB13–DB0
JUMPER CONFIGURATION FOR ONE-PORT MODE PLL OFF
JP1 –
JP2 –
JP3 –
JP5 –
JP6 –
JP12 –
JP24 –
JP25 –
JP26 –
JP27 –
JP31 –
JP32 –
JP33 –
SOLDERED/IN
×
×
×
×
×
UNSOLDERED/OUT
×
×
×
×
×
×
×
×
02858-104
NOTES
1. TO USE PECL CLOCK DRIVER, SOLDER JP41 AND JP42 AND REMOVE TRANSFORMER T1.
Figure 104. Test Configuration for AD9775 in One-Port Mode with PLL Disabled, DAC Output Data Rate = Signal Generator Frequency,
ONEPORTCLK = Interleaved Input Data Rate = 2× Signal Generator Frequency/Interpolation Rate