Datasheet

Data Sheet ADE5166/ADE5169/ADE5566/ADE5569
Rev. D | Page 131 of 156
Table 144. Common Baud Rates Using the UART Timer with a 4.096 MHz PLL Clock
Ideal Baud CD SBTH DIV SBAUDT SBAUDF % Error
115,200 0 0 1 0x01 0x87 +0.16
115,200 1 0 0 0x00 0x87 +0.16
57,600 0 0 2 0x02 0x87 +0.16
57,600 1 0 1 0x01 0x87 +0.16
38,400 0 0 2 0x02 0xAB 0.31
38,400 1 0 1 0x01 0xAB 0.31
38,400 2 0 0 0x00 0xAB 0.31
19,200 0 0 3 0x03 0xAB 0.31
19,200 1 0 2 0x02 0xAB 0.31
19,200 2 0 1 0x01 0xAB 0.31
19,200 3 0 0 0x00 0xAB 0.31
9600 0 0 4 0x04 0xAB 0.31
9600 1 0 3 0x03 0xAB 0.31
9600 2 0 2 0x02 0xAB 0.31
9600 3 0 1 0x01 0xAB 0.31
9600 4 0 0 0x00 0xAB 0.31
4800 0 0 5 0x05 0xAB 0.31
4800 1 0 4 0x04 0xAB 0.31
4800 2 0 3 0x03 0xAB 0.31
4800 3 0 2 0x02 0xAB 0.31
4800 4 0 1 0x01 0xAB 0.31
4800 5 0 0 0x00 0xAB 0.31
2400 0 0 6 0x06 0xAB 0.31
2400 1 0 5 0x05 0xAB 0.31
2400 2 0 4 0x04 0xAB 0.31
2400 3 0 3 0x03 0xAB 0.31
2400 4 0 2 0x02 0xAB 0.31
2400 5 0 1 0x01 0xAB 0.31
2400 6 0 0 0x00 0xAB 0.31
300
0
2
7
0x17
0xAB
0.31
300 1 1 7 0x0F 0xAB 0.31
300 2 0 7 0x07 0xAB 0.31
300 3 0 6 0x06 0xAB 0.31
300 4 0 5 0x05 0xAB 0.31
300
5
0
4
0x04
0xAB
0.31
300 6 0 3 0x03 0xAB 0.31
300 7 0 2 0x02 0xAB 0.31