Data Sheet ADE5166/ADE5169/ADE5566/ADE5569
Rev. D | Page 23 of 156
–2.0
–1.5
–1.0
–0.5
0
0.5
1.0
2.0
1.5
0.1 1 10 100
MID CLASS C
MID CLASS C
07411-138
CURRENT CHANNEL (% of Full Scale)
ERROR (% of Reading)
GAIN = 16
INTEGRATOR OFF
INTERNAL REFERENCE
+25°C
;
PF = 1
–40°C
;
PF = 1
+85°C
;
PF = 1
Figure 23. Active Energy Error as a Percentage of Reading (Gain = 16)
over Temperature with Internal Reference, Integrator Off
–2.0
–1.5
–1.0
–0.5
0
0.5
1.0
2.0
1.5
0.1 1 10 100
MID CLASS C
MID CLASS C
07411-139
CURRENT CHANNEL (% of Full Scale)
ERROR (% of Reading)
+25°C
;
PF = 1
+25°C
;
PF = 0.5
–40°C
;
PF = 0.5
–40°C
;
PF = 1
+85°C
;
PF = 0.5
GAIN = 16
INTEGRATOR OFF
INTERNAL REFERENCE
+85°C
;
PF = 1
Figure 24. Active Energy Error as a Percentage of Reading (Gain = 16)
over Power Factor with Internal Reference, Integrator Off
–1.0
–0.8
–0.6
–0.4
–0.2
0
0.2
0.4
0.6
0.8
1.0
0.1 1 10 100
07411-140
CURRENT CHANNEL (% of Full Scale)
ERROR (% of Reading)
GAIN = 16
INTEGRATOR OFF
INTERNAL REFERENCE
+85°C; PF = 0
–40°C; PF = 0
+25°C; PF = 0
Figure 25. Reactive Energy Error as a Percentage of Reading (Gain = 16)
over Temperature with Internal Reference, Integrator Off
–1.0
–0.8
–0.6
–0.4
–0.2
0
0.2
0.4
0.6
0.8
1.0
0.1 1 10 100
07411-141
CURRENT CHANNEL (% of Full Scale)
ERROR (% of Reading)
GAIN = 16
INTEGRATOR OFF
INTERNAL REFERENCE
+85°C; PF = 0
–40°C; PF = 0
–40°C; PF = 0.866
+25°C; PF = 0
+25°C; PF = 0.866
+85°C; PF = 0.866
Figure 26. Reactive Energy Error as a Percentage of Reading (Gain = 16)
over Power Factor with Internal Reference, Integrator Off
–2.0
–1.5
–1.0
–0.5
0
0.5
1.0
2.0
1.5
0.1 1 10 100
MID CLASS C
MID CLASS C
07411-142
CURRENT CHANNEL (% of Full Scale)
ERROR (% of Reading)
GAIN = 16
INTEGRATOR OFF
INTERNAL REFERENCE
+25°C
;
PF = 1
+85°C
;
PF = 1
–40°C
;
PF = 1
Figure 27. Current RMS Error as a Percentage of Reading (Gain = 16)
over Temperature with Internal Reference, Integrator Off
–2.0
–1.5
–1.0
–0.5
0
0.5
1.0
2.0
1.5
0.1 1 10 100
MID CLASS C
MID CLASS C
07411-143
CURRENT CHANNEL (% of Full Scale)
ERROR (% of Reading)
GAIN = 16
INTEGRATOR OFF
INTERNAL REFERENCE
+25°C
;
PF = 1
+85°C
;
PF = 1
+85°C
;
PF = 0.5
+25°C
;
PF = 0.5
–40°C
;
PF = 1
–40°C
;
PF = 0.5
Figure 28. Current RMS Error as a Percentage of Reading (Gain = 16)
over Power Factor with Internal Reference, Integrator Off