TERMINOLOGY
R
ON
Ohmic resistance between D and S.
R
ON
Match
Difference between the R
ON
of any two channels.
I
S
(OFF)
Source leakage current with the switch OFF.
I
D
(OFF)
Drain leakage current with the switch OFF.
I
D
, I
S
(ON)
Channel leakage current with the switch ON.
V
D
(V
S
)
Analog voltage on Terminals D, S.
C
S
(OFF)
OFF switch source capacitance.
C
D
(OFF)
OFF switch drain capacitance.
C
D
, C
S
(ON)
ON switch capacitance.
t
ON
Delay between applying the digital control input and the output
switching on.
t
OFF
Delay between applying the digital control input and the output
switching off.
t
OPEN
Break-before-make delay when switches are configured as a
multiplexer.
Crosstalk
A measure of unwanted signal which is coupled through from
one channel to another as a result of parasitic capacitance.
Off Isolation
A measure of unwanted signal coupling through an OFF switch.
Charge Injection
A measure of the glitch impulse transferred from the digital
input to the analog output during switching.