Datasheet

Data Sheet ADM1275
Rev. D | Page 45 of 48
Bits Bit Name Settings Description
1 GPO2_EN 0
Default. GPO/
ALERT2 is configured as an SMBAlert output.
1
GPO/
ALERT2 is configured as a general-purpose output.
0 GPO2_DATA 0
Default. Sets GPO/
ALERT2 low when configured as a general-purpose output.
1
Sets GPO/
ALERT2 high when configured as a general-purpose output.
DEVICE_CONFIG
Code: 0xD8, read/write byte. Value after reset: 0x00.
Table 40. Bit Descriptions for DEVICE_CONFIG Command
Bits Bit Name Settings Description
7 OC_GLITCH_TIME 0
Default. The long duration glitch filter is used when a severe overcurrent fault is
detected.
1
The short duration glitch filter is used when a severe overcurrent fault is detected.
6 FLB_DISABLE 0 Default. Foldback is enabled and can affect the hot-swap current sense limit.
1
Foldback is disabled and does not affect the hot-swap current sense limit. This setting
can be useful if the sole purpose of the FLB pin is to act as a power-good input.
5 OPERATION_CMD_EN 0
Default. The OPERATION command is disabled, and the ADM1275 issues a NACK if
the command is received. This setting provides some protection against a card
accidentally turning itself off.
1 The OPERATION command is enabled, and the ADM1275 responds to it.
4 IOUT_WARN2_SELECT 0 Default. Configures IOUT_WARN2_LIMIT as an undercurrent threshold.
1 Configures IOUT_WARN2_LIMIT as an overcurrent threshold.
[3:0] Reserved 0000 Always reads as 0000.
POWER_CYCLE
Code: 0xD9, send byte, no data.