Datasheet
ADM3051 Data Sheet
Rev. 0 | Page 8 of 16
350
0
50
150
100
–50 125
PROPAGATION DELAY TxD OFF T
O
RECEIVER INACTIVE (SLOPE MODE),
t
offRxD
(ns)
TEMPERATURE (°C)
10029-016
200
250
300
–25 0 25 50 75 100
Figure 9. Propagation Delay (Slope Control Mode, R
SLOPE
= 47 kΩ) from TxD
Off to Receiver Inactive vs. Temperature
315
270
4.5 5.5
PROPAGATION DELAY TxD OFF TO
RECEIVER INACTIVE (SLOPE MODE),
t
offRxD
(ns)
SUPPLY VOLTAGE (V)
10029-017
4.6 4.7 4.8 4.9 5.0 5.1 5.2 5.3 5.4
275
280
285
290
295
300
305
310
Figure 10. Propagation Delay (Slope Control Mode, R
SLOPE
= 47 kΩ) from TxD
Off to Receiver Inactive vs. Supply Voltage
184
166
–50 125
RECEIVER INPUT HYSTERESIS (mV)
TEMPERATURE (°C)
10029-018
–25 0 25 50 75 100
168
170
172
174
176
178
180
182
Figure 11. Receiver Input Hysteresis vs. Temperature
35
0
5
15
10
–50 125
PROPAGATION DELAY FROM TxD OFF TO
BUS INACTIVE,
t
offTxD
(ns)
TEMPERATURE (°C)
10029-019
20
25
30
–25 0 25 50 75 100
Figure 12. Propagation Delay from TxD Off to Bus Inactive vs. Temperature
29.0
24.5
4.5 5.5
PROPAGATION DELAY FROM TxD OFF TO
BUS INACTIVE,
t
offTxD
(ns)
SUPPLY VOLTAGE (V)
10029-020
4.6 4.7 4.8 4.9 5.0 5.1 5.2 5.3 5.4
25.0
25.5
26.0
26.5
27.0
27.5
28.0
28.5
Figure 13. Propagation Delay from TxD Off to Bus Inactive vs. Supply Voltage
41
33
–50 125
PROPAGATION DELAY FROM TxD ON T
O
BUS ACTIVE,
t
onTxD
(ns)
TEMPERATURE (°C)
10029-021
–25 0 25 50 75 100
34
35
36
37
38
39
40
Figure 14. Propagation Delay from TxD On to Bus Active vs. Temperature