Datasheet

ADM6326/ADM6328/ADM6346/ADM6348
Rev. 0 | Page 4 of 12
ABSOLUTE MAXIMUM RATINGS
Table 3.
Parameter Rating
Supply Voltage, V
CC
−0.3 V to +6 V
Input Current, I
CC
20 mA
Output Voltage
Push-Pull
RESET
−0.3 V to (V
CC
+ 0.3 V)
Open-Drain
RESET
−0.3 V to +6 V
Output Current (
RESET
)
20 mA
Rate of Rise of V
CC
100 V/μs
Temperature
Storage −65°C to +155°C
Operating −40°C to +85°C
Soldering (10 sec) 300°C
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
THERMAL RESISTANCE
θ
JA
is specified for the worst-case conditions, that is, a device
soldered in a circuit board for surface-mount packages.
Table 4. Thermal Resistance
Package Type θ
JA
Unit
3-Lead SOT-23 270 °C/W
ESD CAUTION