Data Sheet ADP151
Rev. E | Page 3 of 24
SPECIFICATIONS
V
IN
= (V
OUT
+ 0.4 V) or 2.2 V, whichever is greater; EN = V
IN
, I
OUT
= 10 mA, C
IN
= C
OUT
= 1 µF, T
A
= 25°C, unless otherwise noted.
Table 1.
Parameter Symbol Conditions Min Typ Max Unit
INPUT VOLTAGE RANGE V
IN
T
J
= −40°C to +125°C 2.2 5.5 V
OPERATING SUPPLY CURRENT I
GND
I
OUT
= 0 µA 10 µA
I
OUT
= 0 µA, T
J
= −40°C to +125°C 20 µA
I
OUT
= 100 µA 20 µA
I
OUT
= 100 µA, T
J
= −40°C to +125°C 40 µA
I
OUT
= 10 mA 60 µA
I
OUT
= 10 mA, T
J
= −40°C to +125°C 90 µA
I
OUT
= 200 mA 265 μA
I
OUT
= 200 mA, T
J
= −40°C to +125°C
350
μA
SHUTDOWN CURRENT I
GND-SD
EN = GND 0.2 µA
EN = GND, T
J
= −40°C to +125°C 1.0 µA
OUTPUT VOLTAGE ACCURACY
V
OUT
I
OUT
= 10 mA −1 +1 %
TSOT/LFCSP V
OUT
T
J
= −40°C to +125°C
V
OUT
< 1.8 V
100 µA < I
OUT
< 200 mA, V
IN
= (V
OUT
+ 0.4 V) to 5.5 V −3 +2 %
V
OUT
1.8 V
100 µA < I
OUT
< 200 mA, V
IN
= (V
OUT
+ 0.4 V) to 5.5 V 2.5 +1.5 %
WLCSP V
OUT
T
J
= −40°C to +125°C
V
OUT
< 1.8 V
100 µA < I
OUT
< 200 mA, V
IN
= (V
OUT
+ 0.4 V) to 5.5 V 2.5 +2 %
V
OUT
1.8 V
100 µA < I
OUT
< 200 mA, V
IN
= (V
OUT
+ 0.4 V) to 5.5 V −2 +1.5 %
REGULATION
Line Regulation ∆V
OUT
/∆V
IN
V
IN
= (V
OUT
+ 0.4 V) to 5.5 V, T
J
= −40°C to +125°C −0.05 +0.05 %/V
Load Regulation (TSOT/LFCSP)
1
∆V
OUT
/∆I
OUT
V
OUT
< 1.8 V %/mA
I
OUT
= 100 µA to 200 mA 0.006 %/mA
I
OUT
= 100 µA to 200 mA, T
J
= −40°C to +125°C 0.012 %/mA
V
OUT
1.8 V
I
OUT
= 100 µA to 200 mA 0.003 %/mA
I
OUT
= 100 µA to 200 mA, T
J
= −40°C to +125°C 0.008 %/mA
Load Regulation (WLCSP)
1
∆V
OUT
/∆I
OUT
V
OUT
< 1.8 V %/mA
I
OUT
= 100 µA to 200 mA 0.004 %/mA
I
OUT
= 100 µA to 200 mA, T
J
= −40°C to +125°C
0.009
%/mA
V
OUT
1.8 V
I
OUT
= 100 µA to 200 mA 0.002 %/mA
I
OUT
= 100 µA to 200 mA, T
J
= −40°C to +125°C 0.006 %/mA
DROPOUT VOLTAGE
2
V
DROPOUT
I
OUT
= 10 mA 10 mV
I
OUT
= 10 mA, T
J
= −40°C to +125°C 30 mV
TSOT/LFCSP I
OUT
= 200 mA 150 mV
I
OUT
= 200 mA, T
J
= −40°C to +125°C 230 mV
WLCSP I
OUT
= 200 mA 135 mV
I
OUT
= 200 mA, T
J
= −40°C to +125°C 200 mV