Datasheet

ADP160/ADP161/ADP162/ADP163 Data Sheet
Rev. H | Page 4 of 24
Parameter Symbol Conditions Min Typ Max Unit
UNDERVOLTAGE LOCKOUT UVLO
Input Voltage Rising UVLO
RISE
2.19 V
Input Voltage Falling UVLO
FALL
1.60 V
Hysteresis UVLO
HYS
100 mV
OUTPUT NOISE OUT
NOISE
10 Hz to 100 kHz, V
IN
= 5 V, V
OUT
= 3.3 V 105
µV
rms
10 Hz to 100 kHz, V
IN
= 5 V, V
OUT
= 2.5 V 100
µV
rms
10 Hz to 100 kHz, V
IN
= 5 V, V
OUT
= 1.2 V 80
µV
rms
POWER SUPPLY REJECTION RATIO
PSRR
IN
OUT
60
dB
100 Hz, V
IN
= 5 V, V
OUT
= 2.5 V 65 dB
100 Hz, V
IN
= 5 V, V
OUT
= 1.2 V 72 dB
1 kHz, V
IN
= 5 V, V
OUT
= 3.3 V 50 dB
1 kHz, V
IN
= 5 V, V
OUT
= 2.5 V 50 dB
1 kHz, V
IN
= 5 V, V
OUT
= 1.2 V 62 dB
1
Accuracy when VOUT is connected directly to ADJ. When the VOUT voltage is set by external feedback resistors, the absolute accuracy in adjust mode depends on the
tolerances of resistors used.
2
Based on an end-point calculation using 0 μA and 150 mA loads.
3
Dropout voltage is defined as the input-to-output voltage differential when the input voltage is set to the nominal output voltage. This applies only for output
voltages above 2.2 V.
4
Start-up time is defined as the time between the rising edge of EN to V
OUT
being at 90% of its nominal value.
5
Current limit threshold is defined as the current at which the output voltage drops to 90% of the specified typical value. For example, the current limit for a 3.0 V
output voltage is defined as the current that causes the output voltage to drop to 90% of 3.0 V or 2.7 V.
INPUT AND OUTPUT CAPACITOR, RECOMMENDED SPECIFICATIONS
Table 2.
Parameter Symbol Conditions Min Typ Max Unit
MINIMUM INPUT AND OUTPUT CAPACITANCE
1
C
MIN
T
A
= −40°C to +125°C 0.7 µF
CAPACITOR ESR R
ESR
T
A
= −40°C to +125°C 0.001 0.2 Ω
1
The minimum input and output capacitance should be greater than 0.7 µF over the full range of operating conditions. The full range of operating conditions in the
application must be considered during device selection to ensure that the minimum capacitance specification is met. X7R and X5R type capacitors are recommended;