Datasheet

Table Of Contents
Rev. J | Page 22 of 60 | July 2013
ADSP-21362/ADSP-21363/ADSP-21364/ADSP-21365/ADSP-21366
Timer WDTH_CAP Timing
The following timing specification applies to Timer0, Timer1,
and Timer2 in WDTH_CAP (pulse width count and capture)
mode. Timer signals are routed to the DAI_P20–1 pins through
the SRU. Therefore, the timing specification provided below are
valid at the DAI_P20–1 pins.
DAI Pin to Pin Direct Routing
For direct pin connections only (for example, DAI_PB01_I to
DAI_PB02_O).
Table 16. Timer Width Capture Timing
Parameter Min Max Unit
Timing Requirement
t
PWI
Timer Pulse Width 2 × t
PCLK
2 × (2
31
– 1) × t
PCLK
ns
Figure 13. Timer Width Capture Timing
TIMER
CAPTURE
INPUTS
t
PWI
Table 17. DAI Pin to Pin Routing
Parameter Min Max Unit
Timing Requirement
t
DPIO
Delay DAI Pin Input Valid to DAI Output Valid 1.5 10 ns
Figure 14. DAI Pin to Pin Direct Routing
DAI_Pn
DAI_Pm
t