Temperature Value Register
This 16-bit read only register stores the temperature measured by the internal temperature sensor. The temperature is stored in twos
complement format with the MSB being the temperature sign bit. When reading from this register, the eight MSBs (Bit D15 to Bit D8) are
read first and then the eight LSBs (Bit D7 to Bit D0) are read. The control register settings are the default settings on power up.
MSB
LSB
D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
0 0 0 0 0 0 0 0 0 0 0 0 N/A N/A N/A N/A
Configuration Register
This 8-bit read/write register stores various configuration modes for the ADT75. These modes are shutdown, overtemperature interrupt,
one-shot, SMBus alert function enable, OS/ALERT pin polarity, and overtemperature fault queues.
Table 10.
Bit Configuration Mode Default Setting at Power-Up
D7 OS/SMBus alert 0
D6 Reserved 0
D5 One-shot 0
D4 Fault queue 0
D3 Fault queue 0
D2 OS/ALERT pin polarity 0
D1 Cmp/Int 0