PACKAGE CHARACTERISTICS
Table 8.
Parameter Symbol Min Typ Max Unit Test Conditions/Comments
Resistance (Input-to-Output)
1
R
I-O
10
12
Capacitance (Input-to-Output)
1
C
I-O
1.0 pF f = 1 MHz
Input Capacitance C
I
4.0 pF
IC Junction-to-Case Thermal Resistance, Side 1 θ
JCI
46 °C/W Thermocouple located at
center of package underside
IC Junction-to-Case Thermal Resistance, Side 2 θ
JCO
41 °C/W
1
The device is considered a 2-terminal device; Pin 1, Pin, 2, Pin 3, and Pin 4 are shorted together, and Pin 5, Pin 6, Pin 7, and Pin 8 are shorted together.
REGULATORY INFORMATION
The ADuM1200/ADuM1201 and ADuM1200W/ADuM1201W are approved by the organizations listed in Table 9; refer to Table 14 and
the Insulation Lifetime section for details regarding recommended maximum working voltages for specific cross-isolation waveforms and
insulation levels.
Table 9.
UL CSA CQC VDE
Recognized Under 1577
Component Recognition
Program
1
Approved under CSA Component
Acceptance Notice 5A
Approved under
CQC11-471543-2012
Certified according to
DIN V VDE V 0884-10
(VDE V 0884-10): 2006-12
2
Single/Basic 2500 V rms
Isolation Voltage
Basic insulation per CSA 60950-1-03 and IEC
60950-1, 400 V rms (566 peak) maximum
working voltage
Basic insulation per
GB4943.1-2011
Reinforced insulation,
560 V peak
Functional insulation per CSA 60950-1-03 and
IEC 60950-1, 800 V rms (1131 V peak)
maximum working voltage
Basic insulation, 400 V rms
(588 V peak) maximum
working voltage, tropical
climate, altitude5000 m
File E214100 File 205078 File CQC14001114901 File 2471900-4880-0001
1
In accordance with UL 1577, each ADuM1200, ADuM1201, ADuM1200W, and ADuM1201W is proof tested by applying an insulation test voltage ≥ 3000 V rms for 1 sec
(current leakage detection limit = 5 µA).
2
In accordance with DIN V VDE V 0884-10, each ADuM1200, ADuM1201, ADuM1200W, and ADuM1201W is proof tested by applying an insulation test voltage ≥ 1050 V
peak for 1 sec (partial discharge detection limit = 5 pC). The * and/or & marking branded on the component designates DIN V VDE V 0884-10
approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 10.
Parameter Symbol Value Unit Conditions
Rated Dielectric Insulation Voltage 2500 V rms 1 minute duration
Minimum External Air Gap (Clearance) L(I01) 4.90 min mm Measured from input terminals to output terminals,
shortest distance through air
Minimum External Tracking (Creepage) L(I02) 4.01 min mm Measured from input terminals to output terminals,
shortest distance path along body
Minimum Internal Gap (Internal Clearance) 0.017 min mm Insulation distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >400 V DIN IEC 112/VDE 0303 Part 1
Isolation Group II Material Group (DIN VDE 0110, 1/89, Table 1)