Datasheet

ADuM1400/ADuM1401/ADuM1402
Rev. D | Page 12 of 24
PACKAGE CHARACTERISTICS
Table 4.
Parameter Symbol Min Typ Max Unit Test Conditions
Resistance (Input-to-Output)
1
R
I-O
10
1, 2
Ω
Capacitance (Input-to-Output)
1
C
I-O
2.2 pF f = 1 MHz
Input Capacitance
2
C
I
4.0 pF
IC Junction-to-Case Thermal Resistance, Side 1 θ
JCI
33 °C/W
IC Junction-to-Case Thermal Resistance, Side 2 θ
JCO
28 °C/W
Thermocouple located
at center of package
underside
1
Device considered a 2-terminal device; Pins 1, 2, 3, 4, 5, 6, 7, and 8 shorted together and Pins 9, 10, 11, 12, 13, 14, 15, and 16 shorted together.
2
Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
The ADuM140x have been approved by the organizations listed in Table 5.
Table 5.
UL
1
CSA VDE
2
TÜV
Recognized under
1577 component
recognition
program
1
Approved under CSA
Component
Acceptance Notice #5A
Certified according to DIN EN 60747-5-2
(VDE 0884 Part 2): 2003-01
2
Approved according to:
IEC 61010-1:2001 (2
nd
Edition),
EN 61010-1:2001 (2
nd
Edition)
UL 61010-1:2004
CSA C22.2.61010.1:2005
Double/reinforced
insulation,
2500 V rms
isolation voltage
Reinforced insulation per
CSA 60950-1-03 and
IEC 60950-1,
400 V rms maximum
working voltage
Basic insulation, 560 V peak
Reinforced insulation,
400 V rms maximum working
voltage
Complies with DIN EN 60747-5-2 (VDE 0884 Part 2):
2003-01,
DIN EN 60950 (VDE 0805): 2001-12; EN 60950: 2000
Reinforced insulation, 560 V peak
File E214100 File 205078 File 2471900-4880-0001 Certificate U8V 05 06 56232 002
1
In accordance with UL1577, each ADuM140x is proof tested by applying an insulation test voltage ≥3000 V rms for 1 sec (current leakage detection limit = 5 μA).
2
In accordance with DIN EN 60747-5-2, each ADuM140x is proof tested by applying an insulation test voltage ≥1050 V peak for 1 sec (partial discharge detection
limit = 5 pC). The * marking branded on the component designates DIN EN 60747-5-2 approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter Symbol Value Unit Conditions
Rated Dielectric Insulation Voltage 2500 V rms 1 minute duration
Minimum External Air Gap (Clearance) L(I01) 7.7 min mm
Measured from input terminals to output terminals,
shortest distance through air
Minimum External Tracking (Creepage) L(I02) 8.1 min mm
Measured from input terminals to output terminals,
shortest distance path along body
Minimum Internal Gap (Internal Clearance) 0.017 min mm Insulation distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >175 V DIN IEC 112/VDE 0303 Part 1
Isolation Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1)